Fire-Rated Drywall Installation
We hang fire-rated drywall, often called Type X, where your drawings call for it, fastened exactly as the listed assembly specifies.
Or email patleroy6161@gmail.com
About this service
Fire-rated board, often called Type X, has a core made with glass fibres. It holds together longer in a fire than regular board. It is commonly 5/8 inch thick.
The rating does not belong to the board alone. It belongs to the whole assembly: board, framing, fasteners, spacing and layers. So we hang it exactly as the drawings and the listed assembly specify. This often comes up on the wall and ceiling between an attached garage and the house, and between units in multi-unit buildings. Send us your drawings with the form, call (365) 499-0040 or email patleroy6161@gmail.com. We have over 20 years in the trade.
What this covers
- Hanging Type X fire-rated board where the drawings call for it
- Fastening and spacing screws as the listed assembly specifies
- Hanging extra layers when the rated assembly calls for them
- Garage-to-house walls and ceilings hung to the permit drawings
- Walls and ceilings between units in multi-unit buildings
Where we do fire-rated drywall installation
Fire-Rated Drywall Installation: questions
What does Type X mean on my drawings?
Type X is a common name for fire-rated drywall. Its core is made with glass fibres, so it holds together longer in a fire than regular board. When drawings call for it, we hang it there.
Why does the whole assembly matter and not just the board?
A rating is tested on a full build-up: the board, the framing behind it, the fasteners, their spacing and the number of layers. Change one part and it is no longer the listed assembly. We hang to that listing.
Does the wall between my attached garage and house need special board?
The wall between an attached garage and the house is usually subject to building code requirements. We hang the board on that wall as your permit drawings specify, including any fire-rated board they call for.
Can a rated wall between units also control sound?
Often, yes. Walls between units are frequently rated for both fire and sound. Sound control comes from the whole assembly, including layers, resilient channel, cavity insulation and acoustic sealant. We hang the board to the specified assembly.
When in the build does rated board go up?
Board usually goes up after framing, plumbing, electrical and ductwork rough-ins are done, and after insulation and vapour barrier are in. Rated board follows the same order as other board.
My addition joins an attached garage. Can you hang that rated wall?
Yes. On an addition, new board often has to meet existing walls or ceilings where it joins the house. Where the drawings call for a rated wall, we hang it as they specify.
Book an on-site quote
Calling is fastest:
(365) 499-0040Email: patleroy6161@gmail.com
Or send the form with the rooms, ceiling heights and timing. Quotes are given on site, so we will arrange a visit.
We install the drywall only. The board is supplied by others, and taping and finishing are done by others.